Electrical... | Answered 15 minutes ago


Since you indicate that two remotes do not work, I am guessing the receiver on the opener is the problem. Verify that connections to the terminals (located where the wires from your hardline buttons are connected) are intact.

Electrical... | Answered 2 days ago


Are there any faults listed on the control display? If display is dark then likely a battery issue. Check battery voltage with a Digital Multi Meter (DMM). It should be at least 12.5VDC.

Kohler... | Answered 3 days ago


Sounds Like possibly the regulator is the issue.
Flightsystems Can test these to see if it is good or not.
also here is a link for the service manual
https://us.v-cdn.net/5020499/uploads/editor/0c/g1lx13xi2vyy.pdf

Kohler... | Answered on Apr 16, 2019


the parts manual is a tp-5317 which I do not have . You said its a dec2? or a fast response 2? What is the part number off the main circuit board in the control box?

Kohler... | Answered on Apr 16, 2019


make and model?

Electrical... | Answered on Apr 16, 2019


if you have an scr pack, that has 6 pins, there are two for ac, two for gates, and two for the excitation field.
The two gate wires come off your adc controller.

Kohler... | Answered on Apr 16, 2019


I would try disconnecting the oil pressure sensor temporarily to isolate that circuit as the possible cause of it shutting down.

Kipor Electrical... | Answered on Apr 15, 2019


I finally solved the intermittant starting problem on my Kohler 12 RES by replacing the strater and the starter relay. I was also experiencing the occassional OC indication, red blinking LEDs on the ATS, and intermittent non-starts during the weekly exercises. The problem happened during power outages a couple times also. If I flipped the start switch between auto and run quickly the generator would occasionally start. Once started, the generator runs fine. I ordered a new starter, which included the starter solenoid. By the way, don't worry about the genuine part thing..the old starter was a Delco made overseas. I ordered a new starter online for $85 (6744N) and it was indentical to the genuine Kohler starter. Replaced the starter and it improved the problem but did not totally solve the intermittent starting. Ordered the starter relay (GM49746) replaced it and the problem is solved.

Kohler 12 kW... | Answered on Apr 14, 2019

Not finding what you are looking for?
Electrical Supplies Logo

24,376 questions posted

Ask a Question

Usually answered in minutes!

Popular Products

Top Electrical Supplies Experts

Craig Butler
Craig Butler

Level 3 Expert

1730 Answers

Gene Haynes

Level 3 Expert

5353 Answers

Brad Brown

Level 3 Expert

18031 Answers

Are you an Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...