SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

gopakumarg43
  • 75871 Answers

SOURCE: I need schematic diagram for sharp blue diamond in regulator stage regulator STR W5453A

If you wish to get some details; check the site linked here. Pull up older posts.
http://electronicshelponline.blogspot.com/
Circuit diagrams of many popular brand TVs and other devices are given. Search the site by type in the "brand name" to your device; (Exclude the model number), or the "regulator IC number "in the "Search box at the top right of the display window of the Homepage" to get gathered related posts

Posted on Jun 10, 2016

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I need schematic diagram for sharp blue diamond in regulator stage regulator STR W5453A


If you wish to get some details; check the site linked here. Pull up older posts.
http://electronicshelponline.blogspot.com/
Circuit diagrams of many popular brand TVs and other devices are given. Search the site by type in the "brand name" to your device; (Exclude the model number), or the "regulator IC number "in the "Search box at the top right of the display window of the Homepage" to get gathered related posts

Jun 10, 2016 | Sharp Televison & Video

1 Answer

How do i check str w5453a ic, and what are the other components besides str


If you wish to get some details; check the site linked here. Pull up older posts. Surf the site with patience. http://electronicshelponline.blogspot.com/
Type in the number of the STR; in the search box [at the top right] of the display window and the Search will start at once as you type in, and will show you all the related posts. It will make surf easy.

Feb 16, 2015 | Televison & Video

1 Answer

How to test AC Volts with multitester


plug it in,


if you have to ask then you should not be using multitester

Jul 12, 2014 | Measuring Tools & Sensors

1 Answer

Over temperature warning light has come on


When the overtemperature light comes on it is an indication of possible failure.
But before panicing check these items first.
1.Condenser clean
2. Condenser fan operating (if so equipped)
3. Clearence around unit to allow proper air flow
4. Is compressor running ? (if not check relay, overload)

The compressor relay's purpose is to start the compressor. A faulty relay can result in the compressor failing to cycle on. The relay is accessed from the lower rear of the refrigerator.
Before testing a compressor relay, unplug the refrigerator to avoid an electrical shock hazard. Also, if the compressor uses a capacitor, it must be discharged first to avoid the risk of electrical shock.
The compressor relay can be accessed by removing the terminal cover box. The cover is held on by tension or with a retaining clip.
Remove the compressor relay by pulling it straight off from the compressor
Pull the wire off of the side terminal of the relay. It is connected with a slip on connector. Firmly pull the connector, do not pull on the wire. You may need to use a pair of needle-nose pliers.
Inspect the connector and terminal for corrosion. If either is corroded they should be cleaned or replaced.
There are two types of relays you may encounter, wire coil and solid state. If the relay has an exposed wound wire coil it can be tested for continuity. Otherwise, the relay is of solid state design and requires specialized equipment for testing.
Test the compressor relay for continuity using a multitester. Set the multitester to the ohms setting X1.
With the relay upside down, place the probes into the terminals labeled "S" and "M". The multitester should display a reading of zero ohms, indicating continuity (or if using a continuity tester, it should light up).

relaytest1b.jpg With the probes still in place, turn the relay over. You should hear the click of the magnetic switch engaging. The multitester should now display an ohm reading of infinity (or the tester should not light up).
Turn the relay upside down again, place the probe on the "S" terminal and place it on the side terminal labeled "L".

relaytest3b.jpg The multitester should now display a reading of zero ohms (continuity). Turn the relay over and the reading should change to infinity.
With the relay upside down place one probe on the "L" terminal and the other probe on terminal labeled "M".

relaytest2b.jpg The multitester should display a reading of zero ohms. Turn the relay over and the reading will stay the same, zero ohms.
If the compressor relay does not pass all of these tests, it should be replaced

Aug 07, 2011 | Swan SR5170 Freezer

1 Answer

How can I check the compressor relay? Is there a way to check and see if it's working?


If it rattles when you shake it it's bad.

There are two types of relays you may encounter, wire coil and solid state. If the relay has an exposed wound wire coil it can be tested for continuity. Otherwise, the relay is of solid state design and requires specialized equipment for testing.Test the compressor relay for continuity using a multitester. Set the multitester to the ohms setting X1.
With the relay upside down, place the probes into the terminals labeled "S" and "M". The multitester should display a reading of zero ohms, indicating continuity (or if using a continuity tester, it should light up).
With the probes still in place, turn the relay over. You should hear the click of the magnetic switch engaging. The multitester should now display an ohm reading of infinity (or the tester should not light up).
Turn the relay upside down again, place the probe on the "S" terminal and place it on the side terminal labeled "L".

The multitester should now display a reading of zero ohms (continuity). Turn the relay over and the reading should change to infinity.
With the relay upside down place one probe on the "L" terminal and the other probe on terminal labeled "M".
The multitester should display a reading of zero ohms. Turn the relay over and the reading will stay the same, zero ohms.
If the compressor relay does not pass all of these tests, it should be replaced.

Mar 03, 2010 | Magic Chef MCWC30MCG Compact Wine Cooler

1 Answer

Describe your frigidaire refrigerators frs26r4cq0


Your condenser fan probably is not running. It's underneath with the compressor. It should be running when the compressor runs. You can place a fan on the floor blowing on the condenser coils till you get it fixed. The fan should spin freely. Test the fan motor for continuity using a multitester. Set the multitester to the ohms setting X10. Place a probe on each terminal. The multitester should display a reading approximately mid-way between infinity and zero ohms. If the motor does not pass this test, it should be replaced. You don't need to test the middle one if you have one.

Nov 02, 2009 | Frigidaire FRT21P5A Top Freezer...

1 Answer

Washer not agitating,it doesdrain but does not agitate


Hello

You need to check and test the lid switch, The lid switch ensures that the lid is closed before enabling the machine to spin or agitate. This feature was added after serious injuries resulted from people reaching into an operating washing machine. For this reason, the lid switch should never be bypassed.
Test the switch for continuity using a multitester. Set the multitester to the ohms setting X1. Place a probe on each terminal. The multitester should display a reading of infinity. Depress the button on the lid switch and the reading should change from a reading of infinity to roughly zero. If it does not pass both of these tests, the switch should be replaced.

Inspect the motor coupler,
Inspect the driver belt (belt drive only)
Inspect under the washer for soot (clutch)
Test the motor
Inspect the pulley
Test the transmission
Inspect the agitator
Inspect the pump coupling
Test the water level switch

Regards
PCmania

Sep 26, 2009 | GE WSM2480DWW Unitized Spacemaker Washer...

2 Answers

The tub won't spin or agitate. We had a service repair person who came out and said it was the motor. We purchased a new motor and have installed it. The tub still won't spin or agitate so it was not...


Hey..

In this case there several tips to fix this problem. One of this tips is to test the lid switch first.

Test the switch for continuity using a multitester. Set the multitester to the ohms setting X1. Place a probe on each terminal. The multitester should display a reading of infinity. Depress the button on the lid switch and the reading should change from a reading of infinity to roughly zero. If it does not pass both of these tests, the switch should be replaced.
Some lid switches also have a fuse, you can visually inspect the fuse or test it for continuity with a multitester. If the fuse is bad, replace it with one of the same rating.
The lid switch ensures that the lid is closed before enabling the machine to spin or agitate. This feature was added after serious injuries resulted from people reaching into an operating washing machine.

Test the timer control
Test the centrifugal switch
Test the water level switch


Inspect the motor coupler
Inspect the driver belt(belt drive only)
Inspect under the washer for soot (clutch)
Test the motor
Inspect the pulley
Test the transmission

This tips are useful if all of this tips are fix.

Good luck!

ICmanServer

Jul 31, 2009 | GE WCVH6260FWW

1 Answer

Power seat, mirrors


no its not hard to replace and test with repair manual haynes or chiltons will do and a multitester consult one of our expert techs online chat or try this
first make sure fuses are good then remove switch and test to see theres power to main switch then each individual switch using multitester at 20Vdc setting
then if theres power to switch and it doesnt work at all replace it,
if there is power but only part of the switch works and it is a multi switch control switch you can test its leads to the motors them selves follow wiring to probe using multitester same setting as you try individual functions up down forward etc and isolate which motor is faulty and replace most motors and switches are dealer items but heres a company may have it
Peach street auto 18003652341

Jul 01, 2008 | 2003 Ford Windstar

Not finding what you are looking for?
Refrigerators Logo

Related Topics:

21 people viewed this question

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts

Charles T Nevin
Charles T Nevin

Level 3 Expert

4070 Answers

John Tripp
John Tripp

Level 3 Expert

4655 Answers

Marvin
Marvin

Level 3 Expert

83054 Answers

Are you a Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...